- All Products
- Hubei Wan'an Environmental Protection - Molded Three Grid Septic Tank
- Model: GM-HFC
- Origin: Hubei
- Product Overview: SMC molded septic tank is composed of three interconnected sealed septic tanks, made of harmless materials such as unsaturated resin, high-strength fiberglass, calcium carbonate, high-performance auxiliary materials, etc., with good anti-corrosion performance and anti leakage function. It is molded in one go and assembled with pre ordered parts on site
- Customized consultation: 0716-2782799; Septic Tank Sales Manager: 15171121919 Technical After sales: 13997583868
Comparison of performance of three commonly used septic tanks
serial number | project | Hand wrapped fiberglass reinforced plastic septic tank | Double urn septic tank | SMC molded septic tank |
one | environment protection | Low sludge volume and long cleaning interval | Small capacity, low sludge volume, short cleaning interval time | Low sludge volume and long cleaning interval |
two | Using raw materials | Using glass fiber reinforced unsaturated polyester resin as a reinforcing material can withstand large strains | Using PE material and adding recycled materials can affect quality and lifespan | Using glass fiber reinforced unsaturated polyester resin and talc powder for integrated molding, unable to withstand large strains |
three | Material stability | Strong heat and cold resistance, not easily deformed | Not heat-resistant or aging resistant | Not heat-resistant or cold resistant, materials are prone to damage |
four | pressure resistance | The wrapped glass reinforced plastic septic tank has a perfectly circular shell and a standard ellipsoidal head, with extremely high compressive strength. After installation and completion of the floor, the trolley can be rolled on the upper part without settling and without deformation | The Shuangweng septic tank adopts vertical docking, and a manure pipe needs to be connected in the middle. The upper part has poor compressive strength | The molded septic tank body is connected, and the internal partition is stuck, resulting in limited compressive strength |
five | leakage | The product is fully formed without the need for splicing, with quick installation and no leakage | Multiple joints are required, which need to be reinforced with screws. The joints are prone to leakage | The two-piece design requires adhesive pads and screws to be joined together, and there is a risk of leakage at the joint |
six | corrosion resistance | Good acid and alkali resistance, with a service life of over 30 years | Moderate corrosion resistance, with a service life of less than 10 years | Moderate corrosion resistance, with a service life of less than 10 years |
seven | manual | 1-2 general workers, easy to install | Two general workers need to cooperate and coordinate | Two general workers need to cooperate and coordinate |
eight | ground improvement | Simple processing | The loose soil around the pool needs to be compacted to maintain flatness, and if necessary, the ground needs to be partially hardened | Simple processing |
nine | construction period | Ready to use from the factory, it can be manufactured, installed, and used on the same day, improving efficiency and shortening the construction period | Due to the need for splicing, installation is complicated and slow | Due to the need for docking, installation is complicated and slow, and the edges of the septic tank are prone to breakage during screw installation |
ten | drainage | There are inlet and outlet ports, and sewage can be directly discharged | Without a water outlet, sewage cannot be directly discharged and needs to be manually cleaned | There are inlet and outlet ports, and sewage can be directly discharged |
eleven | transportation | The transportation cost is high, and there is very little damage during the transportation process | In terms of transportation costs, it is easy to become brittle during the transportation process. | The transportation cost is low, and there is a lot of breakage during the transportation process. |
Technical Requirements
The integrated three format septic tank containers are 1m ³, 1.5m ³, 2m ³, with a three tank ratio of 2:1:3. The cleaning and maintenance port should not be lower than 100mm of the tank body. The tank is divided into three tanks by partitions, and the upper opening of the inlet pipe should not be higher than 50mm from the top of the septic tank body. The outlet should be lower than the inlet.
The interior of the septic tank is connected by fecal pipes, which are installed on two partitions. The fecal pipes must be connected to the partitions by disposable plastic parts, and metal components must not be used at the connection points. Two manure pipes should be staggered left and right when they are at the same level and not in a straight line to slow down the flow rate of liquid in the pool.
Specifications
| Companies | Hubei Wan'an Environmental Protection and Petrochemical Equipment Co., Ltd. |



